For thousands of other reports visit RSC's Mineral Intellingence Map

Fancamp Exploration Ltd.

opaxe

Summary

Project:

Mallard

Deposit:Mallard
Location:Canada
Commodities:Gold
Date:5/15/2019
Report Code:NI43-101
Report Type:Exploration/Drilling Update
Project Stage:Pursuing Resources Definition
Report details:15-5-2019: Fancamp Exploration Ltd. announces an Exploration/Drilling Update report for its Mallard deposit at the Mallard project. Drilling results incl. 17.00m @ 0.14g/t Au, 5ppm Cu, 7ppm Pb, 27ppm Zn from 96.0m. Diamond drill core was logged, and where
Resources:x
CP/QP:[Overall Report]: Peter Smith, Joerg Kleinboeck, Blaine Webster (Internal)
ABSTRACT:Diamond drill core was logged, and where marked for sampling, cut in half, with one half placed in a labelled sample bag, and the remaining half placed back into the core tray and stored in a secured compound. A blank and a standard were inserted in the assay sampling sequence at every 26th and 27th place respectively. All samples were shipped to Activation Laboratories in Ancaster, Ontario. Once the samples are received and dried at the laboratory, the samples are then crushed to 80% passing 10 mesh (2 mm) and then split into 250 g sub-sample size using a Jones Riffle Splitter. These sub-samples are then pulverized (using rings and pucks to 90% passing 200 mesh (0.075 mm) and homogenized prior to analysis. Gold analysis is performed using a 30 g charge by fire assay using lead collection with a silver inquart (1A2 package). The lower detection limit is 5 ppb, and the upper detection limit is 5000 ppb for this analysis. A gravimetric finish (1A3 package) is completed for any samples that return greater than 5000 ppb that includes crushing of the entire sample to -150 mesh and subsequently sieved through a 150 mesh screen. The entire +150 mesh portion is assayed, along with two duplicate cuts of the -150 mesh portion. Results are reported as a calculated weighted average of gold in the entire sample. Results for the 38 element ICP analysis (1E3 package) includes digesting 0.5 g of the sample with aqua regia for 2 hours at 95 °C. The sample is cooled and then diluted with deionized water. The samples are then analyzed using an Agilent 700 series ICP for the 38 element suite. QC for the digestion is 15% for each batch, 2 method reagent blanks, 6 in-house controls, 8 sample duplicates and 5 certified reference materials. An additional 20% QC is performed as part of the instrumental analysis to ensure quality in the areas of instrumental drift. If over limits for base metals are encountered, a sodium peroxide fusion, acid dissolution followed by ICP‐OES is completed.

Full Report

opaxe is a smart software platform that reconfigures and redistributes information and produces business insights to help mining professionals and investors make better decisions. We utilise technology and machine learning for data collection and human intelligence for the value-added services.